• 4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
  • 4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
  • 4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
  • 4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
  • 4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm

4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm

Task: Remote Control
Structure: Combination
Mathematical Model: Wired
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm pictures & photos
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
US $112-149 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Guangdong, China
to see all verified strength labels (29)
  • Overview
  • Model List
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
S271
Signal
Continuous
Function
Automatic Control, Monitoring, Measurement
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Customized
Digital Inputs
4 Channel
Analog Inputs
4 Channel
Relay Outputs
4 Channel
Tem&Hum
1CH
Protocol
Modbus RTU, Modbus TCP, Mqtt
Power Supply
DC 12-36V
Communication
4G
SMS Function
SMS Alert, SMS Set, SMS Inquiry, SMS Command
Alarm Numbers
10 SMS Alarm Numbers Can Be Added
Remote Management
Remote Configuration
Application 1
Server room remote control
Application 2
Data center remote monitoring
Application 3
Security alarm
Application 4
Energy consumption monitoring
Application 5
SMS Alarm
Transport Package
Box
Specification
127x88x30mm
Trademark
BLIIoT
Origin
China
HS Code
8531100000
Production Capacity
10000PCS/Month

Packaging & Delivery

Package Size
24.00cm * 23.00cm * 8.00cm
Package Gross Weight
0.800kg

Product Description

4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm

Model List
Model DI AI DO Tem&
Hum
Storage USB RS485 I/O data points
bool 16Bit 32Bit 64Bit
S270 2 2 2 1 2M 1 x x x x x
S271 4 4 4 1 2M 1 x x x x x
S272 8 6 4 1 32G 1 1 64 64 x x
S274 4 x 4 1 32G 1 1 64 128 64 64
S275 8 6 4 1 32G 1 1 64 128 64 64
Product Description

 

4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
The Industrial 4G Wireless Cellular RTU S271 features 4 digital inputs, 4 analog inputs, 4 relay outputs, 1 temperature and humidity input. The RTU supports Modbus RTU over TCP, Modbus TCP, MQTT protocol. 
The remote monitoring module is designed for remote measurement and control system and remote data acquisition telemetry systems, such as smoke, liquid, water, flow, flood, electricity, power, energy remote monitoring and remote control. 
Inbuilt inter-lock logic programmer and powerful timer program function; 
When alarm occurs, the RTU will notify users by SMS, dialing, and also uploading data to cloud platform, monitoring center. The RTU also can be used as a remote switch, remote I/O, remote smart PLC, timer switches.
 
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
The RTU supports BLIIoT IoT RTU protocol, Modbus RTU over TCP protocol, Modbus TCP protocol, MQTT protocol, which can communicate directly with the server, cloud platform or SCADA.
Detailed Photos
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
Product Parameters
Category Parameter Description
Power Input Voltage DC 12~36V  
Power Consumption Normal: 50mA@12V, Max: 150mA@12V
Output 1 Channel; Voltage: 12~36V DC;      
Current: 1500mA@12V(Max)
Protection Reverse wiring prevention; Surge: 4KV
Backup Battery 3.7V/850mA (It is optional. Default: Without battery)
USB USB 1xMini USB
Digital Input QTY 4 Channel
Type Support both Wet contact and Dry contact
Dry Contact Close: Short circuit; Open: Open circuits
Wet Contact Close: 10~30V; Open: 0~3V
Others DIN0 as a high-speed pulse counter, sampling frequency: 1MHz; DIN1~3 as low-speed pulse counter, anti-shake time can be set 1~2000ms, default 1ms; DIN1 with arm and disarm function;
Protection 2KVrms
Digital Output QTY 4 Channel
Type Relay output (5A@30VDC, 5A@250VAC)
Others The first DO can set time to control by authorize number; Custom setting close and open times
Protection 2KVrms
Analog Input QTY 4 Channel
Type Single-ended input, 4-20mA/0-20mA/0-5V
Resolution 12Bit
Accuracy ±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C
Sampling Rate 200ms
Input Impedance >1M ohms
Temperature&Humidity (AM2301) Resolution 16bit(0.1%RH, 0.1°C)
Sampling Rate 200ms
Temperature Range -40 to +80°C
Accuracy 0.5°C
Humidity Range 0 to 99RH%
Accuracy 3%RH
4G SIM Drawer type, Support 1.8V/3V SIM/UIM card, Built-in 15KV ESD protection
SIM Slot 1
L-E Version GSM/EDGE:900,1800MHz
WCDMA:B1,B5,B8
FDD-LTE:B1,B3,B5,B7,B8,B20
TDD-LTE:B38,B40,B41
L-CE Version GSM/EDGE:900,1800MHz
WCDMA:B1,B8
TD-SCDMA:B34,B39
FDD-LTE:B1,B3,B8
TDD-LTE:B38,B39,B40,B41
L-A Version WCDMA:B2,B4,B5
FDD-LTE:B2,B4,B12
L-AU Version GSM/EDGE:850,900,1800MHz
WCDMA:B1,B2,B5,B8
FDD-LTE:B1,B3,B4,B5,B7,B8,B28
TDD-LTE:B40
L-AF Version WCDMA:B2,B4,B5
FDD-LTE:B2,B4,B5,B12,B13,B14,B66,B71
CAT-1 Version GSM:900,1800
FDD-LTE:B1,B3,B5,B8
TDD-LTE:B34,B38,B39,B40,B41
Software Internet Protocol IPV4, TCP/UDP, Modbus RTU, Modbus TCP, MQTT, BLIIoT IoT RTU
Indicator 4G signal, running, arming and disarming
Configuration PC software configuration, support WIN XP, WIN 7, WIN 8 and WIN 10
Transparent Transmission Support
SMS Command Support
Login Package Support custom login package
Heartbeat Package Support custom heartbeat package
Storage Capable of storing up to 200 historical records
Environment Working -45~85°C, 5~95% RH
Storage -45~105°C, 5~95% RH
Others Shell Metal
Size 127x88x30mm
Protection IP30
Installation DIN Rail mounting, Wall-mounted.
Certifications

4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm

Company Profile

4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm pictures & photos
4CH Analog Digital Input Relay Output SMS RTU for Power Failure Alarm
US $112-149 / Piece
Min. Order: 1 Piece
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
52
Year of Establishment
2021-04-30