Customization: | Available |
---|---|
Task: | Data Colletion |
Structure: | Independent IO module |
Still deciding? Get samples of US$ 136.94/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Industiral Automation 4DIN+4AIN+2AO+4DO Ethernet Remote IO Module for PLC Extension
There are many industrial automation devices such as PLC which have a MODBUS Communications facility available. PLC can be configured as a MODBUS Master, and IO modules are attached to the RS485 configured as RTU slaves. PLC system use M120 Modbus RTU IO Module to increasing the I/O capability of the industrial control system. The Modbus remote IO M120 also supports Modbus TCP server and client, SNMP V1/V2, and MQTT protocol. Which is suitable for wide range of industrial data acquisition and remote monitoring applications.
The M120 Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.
Application
Item | Parameter | Description |
Power | Input voltage |
|
Power consumption | Typical standby power consumption: ≤ 2W | |
Power Output |
|
|
Protection | Reverse wiring prevention; ESD Air: 15KV; Surge: 4KV |
|
Ethernet | Specification | 1 x RJ45, 10M/100Mbps |
Protection | ESD contact: 8KV, Surge: 4KV(10/1000us) | |
Protocol | Modbus RTU, Modbus TCP, MQTT | |
Serial port | QTY | 1 x RS485 |
Baud Rate | 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000 | |
Data Bit | 7, 8 | |
Parity Bit | None, Even, Odd | |
Stop Bit | 0.5, 1, 1.5, 2 | |
Protocol | Modbus RTU(slave), Modbus RTU(master) | |
Protection | ESD contact: 8KV Surge: 4KV(8/20us) | |
Digital input | QTY | 4 channel |
Type | Support Wet contact(NPN, PNP) and Dry contact. Default: Wet contact |
|
Dry contact |
|
|
Wet contact |
|
|
Others | Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz. Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz. |
|
Isolated protection | 2KVrms | |
Sampling Rate | 100Hz | |
Digital output | QTY | 4 channels |
Type | SINK | |
Capacity | 500mA per contact | |
Overvoltage protection | 50VDC | |
Pulse output | The first DO supports pulse output, pulse output frequency: 10Hz~300KHz | |
Analog input (12bit) | QTY | 4 channels |
Method | Differential input | |
Type | 4-20mA, 0-20mA, 0-5V, 0-10V | |
Resolution | 12Bit | |
Accuracy |
|
|
Sampling Rate | 20Hz | |
Input Impedance |
|
|
Analog input (16bit) | QTY |
4 channels
|
Method | Differential input | |
Type | 4-20mA, 0-20mA, 0-5V, 0-10V | |
Resolution |
|
|
Accuracy |
|
|
Input Impedance |
|
|
Analog output | QTY | 2 channels |
Method | Single-ended to ground | |
Type | 0~10VDC | |
Resolution | 12Bit | |
Accuracy |
|
|
Maximum load | 1000mA | |
Software | Protocols | IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT |
Protocol conversion | Support Modbus TCP and RTU protocol conversion Support Modbus RTU to MQTT and Modbus TCP to MQTT |
|
Indicator light | Power, Link, RS485_RXD, RS485_TXD, IO status | |
User configuration | PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10 | |
Map data | bool: 300 16bit: 300 |
|
Login Package | Support custom login package | |
Heartbeat Package | Support custom heartbeat package | |
Environment | Working | -20~70°C, 5~95%RH |
Storage | -40~85°C, 5~95%RH | |
Others | Case | Metal |
Dimension | 82mm×40mm×100mm | |
Protection grade | IP30 | |
Net Weight | 450g | |
Installation | DIN rail mounted, Wall-mounted |
Founded in 2005, Beilai Technology is an innovative manufacturer dedicated to the development and manufacturing of loT devices. Beilai is the pinyin of barium-rhenium in Mandarin. Barium is a lively element, and rhenium is the last element discovered by human beings.
The meaning of barium-rhenium is to be brave in innovation and explore the most cutting-edge technology.
Beilai offer partners with a wide range of hardware including Industrial Ethernet I/O Module, Distributed I/O System, Remote I/O Module, Industrial IoT Gateway, Cellular IoT M2M RTU, Embedded ARM Computer, Industrial 4G Edge Router, X86 Embedded Industrial Computer, Remote Battery Measurement System, Cellular SMS Controller, Network Fault Monitoring Alarm, Cellular Gate Opener, OEM and ODM services.
Beilai internal Quality Management System is audited and verified by independent certification bodies against GB/T19001-2016/ISO9001:2015 to prove conformity to internal standards, ISO norms, laws and regulatory requirements.
Exhibition
Certification
Q1. Can you get a free sample?
Yes, you will. but we need to charge for samples, we will return sample fee in later order.
Q2. Can you get better price? or discount?
Yes. we can give you discount. But it is based on quantity. More quantity more attractive price.
Q3.OEM, ODM Severice is available?
Yes.ODOT company provide OEM/ODM service to our customers.
Q4.How about the payment terms?
T/T, Paypal, Credit card
Q5. Can you be responsible for the shipment?
We will organize and schedule all shipping to your office if you need.
Q6. Lead time?
Sample order: 3-6 works days.
Bulk order: 7-30 work days after payment.
Q7. What is your warranty period?
Warranty period is 1 years.
This warranty does not cover damage caused by man-made damage, improper care, improper use, negligence,normal wear and tear, and force majeure such as natura disasters, earthquakes, fires, etc.